saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Discharge Line|Page 11454 > < Discharge Line|Page 11452
Page 1
background image

Hose/Line HVAC: Service and Repair
Suction Pipe

SUCTION PIPE

REMOVAL

1. Disconnect negative battery cable.

IMPORTANT:  Verifying the purity of the refrigerant with a purity identifier before recovery is recommended.

2. Recover refrigerant using an approved refrigerant recovery system. Measure the amount of oil removed during recovery and record.

CAUTION:  DO NOT REMOVE HOSES OR LINES BEFORE SYSTEM IS FULLY DISCHARGED.

3. Remove suction pipe-to-compressor bolt.
4. Remove suction pipe and seal washer from compressor.
5. Install caps on pipe and compressor to prevent moisture entry and oil spillage.

CAUTION:  MAKE SURE VEHICLE IS PROPERLY SUPPORTED AND SQUARELY POSITIONED. TO HELP AVOID PERSONAL
INJURY WHEN A VEHICLE IS ON A HOIST, PROVIDE ADDITIONAL SUPPORT FOR THE VEHICLE ON THE OPPOSITE END
FROM WHICH COMPONENTS ARE BEING REMOVED.

Discharge Line|Page 11454 > < Discharge Line|Page 11452