20. Turn module right side up and use a razor blade to cut defroster/vent seal and blower motor opening seal at center line.

21. Release recirculation door connecting rod from retainer. Remove rod from small door lever and remove. Remove large and small recirculation

doors.

IMPORTANT:  There are two clips and nine screws. Two screws are located in deep cavities.

22. Remove case half retainer clips and screws.

NOTE:  One screw is located at the center of case.