10. Install heater core retaining strap.
11. Install TXV/Heater pipe seal.
12. Install TXV

Torque: 7.0 N.m (62 in-lbs)

13. Install recirculation doors.
14. Install recirculation door rod to small door. With both doors held firmly closed, snap rod into retainer clip and close clip.

15. Install re-circulation actuator assembly onto door shaft. Shaft has two flats that must be aligned to actuator. Install recirculation actuator bracket to

module screws.

Torque: 1.0 N.m (9 in-lbs)