The numbers below refer to the step number on the diagnostic table shown.

3.

This step tests for a high resistance in the signal circuit and the low reference circuit of the fuel level sensor.

14.

Diagnostic Trouble Codes (DTCs) will be set in the Engine Control Module/Powertrain Control Module (ECM/PCM) when you perform this
diagnostic table.

Testing for Intermittent and Poor Connections

Most intermittent conditions are caused by faulty electrical connections or wiring. Inspect for the following items:

^

Duplicate intermittent fault conditions by wiggling the harness, disconnecting and reconnecting connectors, pulling on the mechanical connection of
a connector, pulling on the harness or wire in order to identify a separation/break inside the insulation.

^

Test for electrical intermittent opens, high resistances, short to ground and short to voltage on electrical circuits.

^

Wiring that is broken inside the insulation.