background image

NOTE:  Use only mineral oil to lubricate O-ring seals. Use of PAG oil will cause premature corrosion of joints.

3. Remove shipping caps from thermal expansion valve (TXV) and suction/liquid line assembly.
4. Lubricate suction/liquid line assembly to TXV 0 - rings.
5. Position suction/liquid line assembly to TXV and hand start bolt.

Torque: 7 N.m (62 in-lbs)

6. Remove shipping cap from suction/liquid line assembly and from liquid line.
7. Add any PAG oil that was removed during recovery to liquid line.

IMPORTANT:  Always install new seal washers to reduce refrigerant leaks.

8. Install seal washer and install suction/liquid line assembly to liquid line and hand start nut.

Torque: 12 N.m (106 in-lbs)