saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Refrigerant Pressure Sensor / Switch, HVAC|Service and Repair|Page 895 > < Blower Motor Switch|Service and Repair
Page 1
background image

Refrigerant Pressure Sensor / Switch: Service and Repair

PRESSURE TRANSDUCER

REMOVAL

1. Disconnect pressure transducer electrical connector.

2. Using a back-up wrench to support refrigerant line, remove pressure transducer.

INSTALLATION

NOTE:  Do not use PAG oil.

1. Lubricate pressure port O-ring with mineral oil.
2. Hand start pressure transducer onto pressure port.
3. Using a back-up wrench to support refrigerant line, tighten pressure transducer.

Torque: 7 N.m (62 in-lbs)