saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 1376 > < Diagram Information and Instructions|Page 1374
Page 7
background image

1. Put connector seal (if equipped) on wire and strip approximately 9.5 mm (3/8 in.) of insulation off the wire.
2. Remove insulation from the end of the cut lead and the harness. Recommended strip length is 9.5 mm (3/8 in.). Caution must be used to prevent

cutting the wire strands.

3. Determine proper sleeve for gage of wire.

4. Position stripped ends in sleeve until wires hit the stop in the center of the splice.
5. Hand crimp using the approved crimping tool. Gently tug on wires to make sure they are secure before applying heat to them.

CAUTION:  DO NOT USE MATCH OR OPEN FLAME TO APPLY HEAT TO SEAL.

6. Apply heat using Ultratorch(R) or some other device, heating to 175°C (347°F) until glue flows around edges of sleeve.
7. Check for continuity.
8. Insert the terminal into the connector. Check to make sure the terminal lock tab is engaged by gently tugging on the wire.
9. Replace any terminal position assurance (TPA) devices.

Push-to-Seat Connectors

Diagram Information and Instructions|Page 1376 > < Diagram Information and Instructions|Page 1374