saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Fluid Pump, A/T > < Diagram Information and Instructions|Page 8333
Page 1
background image

Fluid Pressure Sensor/Switch: Service and Repair

REMOVAL

1. Remove transaxle case side cover.
2. Remove TFP switch assembly bolts.
3. Remover TFP switch assembly from control valve body assembly. The TFP switch O-rings are reusable if not damaged, and should remain with

switch assembly.

INSTALLATION

1. Inspect TFP switch assembly in order to verify the condition and correct location of pressure switch O-rings. If necessary, replace O-rings.
2. Install TFP switch assembly onto control valve body assembly, and install bolts.

Torque: 12 Nm (9 ft. lbs.)

3. Install transaxle case side cover.
4. Start engine, warm up transaxle, and check for leaks.
5. Check for proper fluid level.

Fluid Pump, A/T > < Diagram Information and Instructions|Page 8333