saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 9106 > < Diagram Information and Instructions|Page 9104
Page 1
background image

Transmission Position Switch/Sensor: Adjustments

TOOLS REQUIRED:

-

J41545 Transaxle Range Switch Alignment Tool

ADJUSTMENT

1. Shift Transaxle into NEUTRAL position.
2. Remove shift control cable from transaxle range switch lever.

3. Remove transaxle range switch lever nut and lever.
4. Loosen transaxle range switch bolts.

5. Insert J41545 as shown and rotate switch until tool drops into position.
6. Tighten transaxle range switch bolts.

Torque:  20 N.m (15 ft-lbs.)

Diagram Information and Instructions|Page 9106 > < Diagram Information and Instructions|Page 9104