saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 3864 > < Diagram Information and Instructions|Page 3862
Page 9
background image

1. Attach one lead to ground.
2. Touch the other lead to various points along the circuit where voltage should be present.
3. When the bulb illuminates, there is voltage at the point being tested.

Using Connector Test Adapters

USING CONNECTOR TEST ADAPTERS

NOTE: Do not insert test equipment probes into any connector or fuse block terminal. The diameter of the test probes will deform most terminals. A
deformed terminal can cause a poor connection, which can result in system failures. Always use the J 35616 GM Approved Terminal Test Kit in order to
frontprobe terminals. Do not use paper clips or other substitutes as they can damage terminals and cause incorrect measurements.

When using the J 35616 GM-Approved Terminal test kit, ensure the terminal test adaptor choice is the correct size for the connector terminal. Do not
visually choose the terminal test adaptor because some connector terminal cavities may appear larger than the actual terminal in the cavity. Using a
larger terminal test adaptor will damage the terminal. Refer to the label on the inside of the J 35616 GM Approved Terminal test kit for the correct
adaptor along with the connector end view for terminal size.

Using Fused Jumper Wires

USING FUSED JUMPER WIRES

TOOLS REQUIRED

J 36169-A Fused Jumper Wire

IMPORTANT:  A fused jumper may not protect solid state components from being damaged.

The J 36169-A includes small clamp connectors that provide adaptation to most connectors without damage. This fused jumper wire is supplied with a
20-A fuse which may not be suitable for some circuits. Do not use a fuse with a higher rating than the fuse that protects the circuit being tested.

Connector Position Assurance Locks

CONNECTOR POSITION ASSURANCE LOCKS

The connector position assurance (CPA) is a small plastic insert that fits through the locking tabs of the connector. CPAs are used in various connectors
throughout the vehicle. CPAs are also used in all SIR system electrical connectors. The CPA ensures that the connector halves cannot vibrate apart. You
must have the CPA in place in order to ensure good contact between the mating terminals, of the connector.

Terminal Position Assurance Locks

TERMINAL POSITION ASSURANCE LOCKS

The terminal position assurance (TPA) insert resembles the plastic combs used in the control module connectors. The TPA keeps the terminal securely
seated in the connector body. Do not remove the TPA from the connector body unless you remove a terminal for replacement.

Bosch Connectors (BSK)

BOSCH CONNECTORS (BSK)

TOOLS REQUIRED

Diagram Information and Instructions|Page 3864 > < Diagram Information and Instructions|Page 3862