7. Remove the A/C lines from the auxiliary TXV.
8. Remove and discard the sealing washers.
9. Cap or tape the A/C lines.

IMPORTANT: Cap or tape the open A/C refrigerant lines immediately to prevent contamination of the refrigerant system.

10. Remove the auxiliary TXV to evaporator core bolts.
11. Remove the auxiliary TXV from the evaporator core. 
12. Cap or tape off the evaporator core lines.
13. Remove and discard the sealing washers.

INSTALLATION PROCEDURE

1. Remove the cap or tape from the evaporator lines.
2. Install the new sealing washers onto the evaporator lines. 

3. Install the auxiliary TXV to the evaporator core.
4. Install the auxiliary TXV to the evaporator core mounting bolts.