saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Discharge Hose Replacement|Page 16408 > < Discharge Hose Replacement|Page 16406
Page 1
background image

Hose/Line HVAC: Service and Repair
Evaporator Inlet Tube and Evaporator Outlet Tube Replacement (W/C69)

EVAPORATOR TUBE REPLACEMENT - INLET/OUTLET (W/C69)

TOOLS REQUIRED

J 39400-A Halogen Leak Detector

REMOVAL PROCEDURE

IMPORTANT: Cap or tape the open air conditioning (A/C) components immediately in order to prevent system contamination.

1. Remove the air cleaner assembly. 
2. Recover the refrigerant from the A/C system. Refer to Refrigerant Recovery and Recharging.
3. Remove the suction line to evaporator outlet tube bolt (1).
4. Remove the suction line from the evaporator outlet tube.
5. Cap or tape the suction line opening. 
6. Remove and discard the sealing washer (2).

Discharge Hose Replacement|Page 16408 > < Discharge Hose Replacement|Page 16406