TERMINAL REPAIR PROCEDURE

Use the appropriate wire assembly kit available through Saturn Service Parts.
1. Slide the new terminal into the correct cavity at the back of the connector. 
2. Push the terminal into the connector until it locks into place. The new terminal should be even with the other terminals. Insure that the terminal is

locked in place by gently pulling on the wire.

3. Replace the nose piece.
4. Replace the dress cover.

Delphi Connectors (Pull To Seat)

DELPHI CONNECTORS (PULL TO SEAT CONNECTORS)

TERMINAL REMOVAL PROCEDURE

If the terminal is visibly damaged or is suspected of having a faulty connection, the terminal should be replaced.

Follow the steps below in order to repair pull-to-seat connectors.

1. Remove the connector position assurance (CPA) device and/or the secondary lock.
2. Disconnect the connector from the component or separate the connectors for in-line connectors.
3. Remove the terminal position assurance (TPA) device.
4. Insert the proper pick or removal tool into the front of the connector body.

TERMINAL REPAIR PROCEDURE

Use the appropriate wire assembly repair kits available through Saturn Service Parts.

Delphi Connectors (Push To Seat)

DELPHI CONNECTORS (PUSH TO SEAT CONNECTORS)

TERMINAL REMOVAL PROCEDURE

Follow the steps below in order to repair push to seat connectors.

1. Remove the terminal position assurance (TPA) device, the connector position assurance (CPA) device, and/or the secondary lock.
2. Separate the connector halves (1).