saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 10039 > < Diagram Information and Instructions|Page 10037
Page 65
background image

7. Pressing the J 38125-12A (GM P/N 12094429) tool in the release cavity of the terminal you are removing, gently pull the wire out of the back of

the connector. Always remember never use force when pulling a terminal out of a connector. See the release tool cross reference in the Reference
Guide of the J-38125 to ensure that the correct release tool is used.

TERMINAL REPAIR PROCEDURE

Use the appropriate terminal and crimper in the J-38125 in order to replace the terminal.

Tyco/AMP Connectors (Sensor)

TYCO/AMP CONNECTORS (SENSOR)

TOOLS REQUIRED

J-38125Terminal Repair Kit

TERMINAL REMOVAL PROCEDURE

1. Disconnect the connector from the component.

2. Insert the J 38125-11A (GM P/N 12094430) tool into the cavity on the lower right hand face of the connector until the terminal release tang access

panel slides over. 

Diagram Information and Instructions|Page 10039 > < Diagram Information and Instructions|Page 10037