3. When the bulb illuminates, there is voltage at the point being tested.

Using Connector Test Adapters

USING CONNECTOR TEST ADAPTERS

NOTE:  Do not insert test equipment probes into any connector or fuse block terminal. The diameter of the test probes will deform most terminals. A
deformed terminal can cause a poor connection, which can result in system failures. Always use the J 35616 GM-Approved Terminal Test Kit in order to
frontprobe terminals. Do not use paper clips or other substitutes as they can damage terminals and cause incorrect measurements.

When using the J 35616 GM-Approved Terminal test kit, ensure the terminal test adaptor choice is the correct size for the connector terminal. Do not
visually choose the terminal test adaptor because some connector terminal cavities may appear larger than the actual terminal in the cavity. Using a larger
terminal test adaptor will damage the terminal. Refer to the label on the inside of the J 35616 GM-Approved Terminal test kit for the correct adaptor
along with the connector end view for terminal size.

Using Fused Jumper Wires

USING FUSED JUMPER WIRES

TOOLS REQUIRED

J 36169-A Fused Jumper Wire

IMPORTANT:  A fused jumper may not protect solid state components from being damaged.

The J 36169-A includes small clamp connectors that provide adaptation to most connectors without damage. This fused jumper wire is supplied with a
20-A fuse which may not be suitable for some circuits. Do not use a fuse with a higher rating than the fuse that protects the circuit being tested.

AFL/ECP Connectors

AFL/EPC CONNECTORS

TOOLS REQUIRED

J-38125 Terminal Repair Kit

REMOVAL PROCEDURE

Follow the steps below in order to remove terminals from the connector.

1. For connectors with a bolt in the dress cover, turn the bolt counterclockwise to remove the connector from the component. 