saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Diagnostic Aids|Page 4088 > < Diagnostic Aids|Page 4086
Page 78
background image

Important:  When making a repair to any GMLAN network, the original wire length after the repair must be the same length as before the
repair. If the network is a twisted pair, the twist must be maintained after the repair is completed.

GMLAN has 2 types of networks, low speed and high speed. Low speed GMLAN has a single wire and works at slow speeds. High speed GMLAN has 2
wires in a twisted pair and works at higher speeds.

GMLAN Connector Terminal Repair

Important:  A service terminal can be used to replace damaged connector terminals for both high speed and low speed GMLAN systems. When
making a connector terminal repair on a GMLAN high speed system with twisted pair wires, do not untwist the wires more than necessary to
make the repair.

 The terminals in the GMLAN system are made of a special metal. This metal provides the necessary contact integrity for the sensitive, low energy
circuits. These terminals are available in the J-38125. If the individual terminals are damaged on any GMLAN connection, use the appropriate connector
repair procedure in order to repair the terminal. Refer to Connector Repairs for the appropriate connector repair procedure.

GMLAN Wire Repair

Important:  Refer to Wiring Repairs in order to determine the correct wire size for the circuit you are repairing. You must obtain this
information in order to ensure circuit integrity. 

If a wire is damaged, repair the wire by splicing in a new section of wire of the same gage size (0.5 mm, 0.8 mm, 1.0 mm, etc.). Use the DuraSeal splice
sleeves and splice crimping tool from the J-38125. Use the following wiring repair procedures in order to ensure the integrity of the sealed splice.

Important:  You must perform the following procedures in the listed order. Repeat the procedure if any wire strands are damaged. You
must obtain a clean strip with all of the wire strands intact.

1.  Open the harness by removing any tape:

*  Use a sewing seam ripper (available from sewing supply stores) in order to cut open the harness in order to avoid wire insulation damage.
*  Use the DuraSeal splice sleeves on all types of insulation except coaxial.
*  Do not use the DuraSeal splice sleeve to form a splice with more than 2 wires coming together.

2.  Cut as little wire off the harness as possible. You may need the extra length of wire in order to change the location of a splice.

Adjust splice locations so that each splice is at least 40 mm (1.5 in) away from the other splices, harness branches, or connectors.

3.  Strip the insulation:

*  When adding a length of wire to the existing harness, use the same size wire as the original wire.
*  Perform one of the following items in order to find the correct wire size:

Find the wire on the schematic and convert the metric size to the equivalent American wire gage (AWG) size.