saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Variable Valve Timing Solenoid|Locations|Page 3478 > < Variable Valve Timing Solenoid|Locations|Page 3476
Page 1
background image

Variable Valve Timing Solenoid: Service and Repair

Camshaft Position Actuator Solenoid Valve Replacement

Removal Procedure

1.  Remove the intake manifold cover.
2.  Disconnect the intake (1) or exhaust (2) camshaft position actuator solenoid valve electrical connector, as required.

3.  Remove the exhaust (1) camshaft position actuator solenoid valve bolt and valve, as required.
4.  Remove the intake (2) camshaft position (CMP) actuator solenoid valve bolt and valve, as required.
5.  Inspect the solenoid valve O-ring seals from damage, replace as necessary.

Installation Procedure

Variable Valve Timing Solenoid|Locations|Page 3478 > < Variable Valve Timing Solenoid|Locations|Page 3476