Page 77
background image

View of the male half of the connector with female terminals.

4.  While holding the removal tool in place, gently pull the wire out of the back of the connector. Always remember never use force when pulling a

terminal out of a connector.

Repair Procedure

Use the appropriate terminal and follow the instructions in the J-38125.

Location of the terminal in the repair tray and the proper crimp tool can be found in the appropriate connector end view.

GMLAN Wiring Repairs

GMLAN Wiring Repairs

Tools Required

J-38125 Terminal Repair Kit

The GM Local Area Network (GMLAN) System requires special wiring repair procedures due to the sensitive nature of the circuitry. Follow the specific
procedures and instructions when working on GMLAN connectors and terminals.

The tool kit J-38125 contains the following items in order to repair the GMLAN wiring:

*  DuraSeal splice sleeves
*  A wire stripping tool
*  J38125-8 Crimping Tool (GM P/N 12085115)
*  J38125-5 Ultra Torch Special Tool (GM P/N 12085116)

The DuraSeal splice sleeves have the following 2 critical features:

*  A special heat shrink sleeve environmentally seals the splice. The heat shrink sleeve contains a sealing adhesive inside.
*  A cross hatched (knurled) core crimp provides necessary contact integrity for the sensitive, low energy circuits.

The J-38125 also serves as a generic terminal repair kit. The kit contains the following items:

*  A large sampling of common electrical terminals
*  The correct tools in order to attach the terminals to the wires
*  The correct tools in order to remove the terminals from the connectors

GMLAN Repairs