saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Diagnostic Aids|Page 5316 > < Diagnostic Aids|Page 5314
Page 45
background image

4.  Use a small flat-blade tool to slide the terminal position assurance (TPA) up one notch on both ends of the connector. The TPA is located

underneath the wire dress cover.

For the larger terminals insert the J38125-556 (GM P/N 12093647) tool to release the terminals by inserting the tool into the terminal release
cavity. For the smaller terminals insert the J38125-560 (GM P/N 15314260) tool to release the terminals by inserting the tool into the terminal
release cavity. See the release tool cross reference in the Reference Guide of the J-38125 to ensure that the correct release tool is used.

Diagnostic Aids|Page 5316 > < Diagnostic Aids|Page 5314