Page 15
background image

^

Map Light

If the fuse is blown, determine the cause of the blown fuse and repair.

Replace fuse as needed.

If this component is good, go to the next item indicated on the chart.

Security System Main Fuse

Location:
Security system main harness

Type:
5A BUSS fuse

Feeds:
Circuit 340XX

If the following system is operating normally, the fuse is most likely good:

^

Security system

If the fuse is blown, determine the cause of the blown fuse and repair.

Replace fuse as needed.

If this component is good, go to the next item indicated on the chart.

Security System Park Fuse

Location:
Security system main harness

Type:
20A BUSS fuse

Feeds:
340

If the following system is operating normally, the fuse is most likely good:

^

Security system parking lamp flash

If the fuse is blown, determine the cause of the blown fuse and repair.

Replace fuse as needed.

If this component is good, go to the next item indicated on the chart.

GROUNDS

Circuit 155:

Location:
Connects security system module pin B5 to Chassis ground at I/P H-Brace.

Type:
Ring terminal

Check for OPENS/SHORTS. Check for proper torque at 13 mm bolt at left lower H-brace support (25 N-m [18 lbs.ft.]).

Repair as needed.

If this component is good, go to the next item indicated on the chart.

Keyless Entry/Security System - Information|Page 7009 > < Keyless Entry/Security System - Information|Page 7007