saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Keyless Entry/Security System - Information|Page 7091 > < Keyless Entry/Security System - Information|Page 7089
Page 2
background image

1.

If reprogramming the security module, disconnect the negative battery cable and wait ten minutes for the capacitors internal to the security module
to discharge.

2.

Connect the negative battery cable.

3.

On up-level systems, verify that the parking lamps are flashing. If the lamps are not flashing, refer to the cause/complaint chart.

4.

Close all doors and stand outside of the vehicle.

5.

Depress one transmitter button firmly for one full second, then release for two seconds. Repeat this step four more times. On up-level systems
only, the parking lamps will turn on steady while the transmitter button is held down.

6.

Open the driver's door, get in vehicle and close the door.

7.

Cycle the ignition key to the RUN position and then to the OFF position.

8.

Open the driver's door, exit vehicle and close the driver's door.

9.

The security system is programmed.

NOTICE:
Failure to complete all programming steps in sequence may cause system malfunction. If system is not working properly, repeat entire programming
procedure.

GENERAL DESCRIPTION

Valet Switch

The security system valet switch is used to select the desired mode as follows:

^

ON: System is active. System can be armed actively or passively. If armed, system will respond to electrical or shock inputs.

^

SHOCK OFF: System is active. System can be armed actively or passively. If armed, system will only respond to electrical inputs.

^

OFF: System is off.

Light Emitting Diode (LED)

The light emitting diode (LED) indicates the status of the security system as follows:

Flashing once per second:
Active (valet switch On or Shock Off), armed and less than 72 hours have elapsed since system was armed.

Flashing twice per second:
Inactive (valet switch Off) and less than 72 hours have elapsed since ignition was turned Off.

Flashing very rapidly:
The ignition is On (key in RUN position) and one or more doors is open.

Flashing in groups of two:
System was armed. Then the alarm was activated by a door being opened. (Refer to History Feature in Owner's Manual.)

Flashing in groups of four:
System was armed. Then the system was activated due to shock detection. (Refer to History Feature in Owner's Manual.)

Flashing in groups of five:
System was armed. Then the system was activated due to electronic tampering. (Refer to History Feature in Owner's Manual.)

Flashing in groups of seven:
System was armed. Then the system was activated because the valet switch was turned to the OFF position. (Refer to History Feature in Owner's
Manual.)

Flashing in groups of eight:
System was armed. Then the system was activated due to ignition switch tampering. (Refer to History Feature in Owner's Manual.)

Keyless Entry/Security System - Information|Page 7091 > < Keyless Entry/Security System - Information|Page 7089