Radiator Cooling Fan Motor: All Technical Service Bulletins
A/C - Whine or Hum When Blower Motor Turned On

BULLETIN NO.: 93-T-12

ISSUE DATE: March, 1993

GROUP/SEQ.NO.: HVAC-02

CORPORATION NO.: 381101

SUBJECT:
Whine or Hum Coming from HVAC Blower Motor and Fan Assembly (Install Fan Motor Cover)

MODELS AFFECTED:
All 1991-92 Saturns built before, and including VIN NZ191713.

CONDITION:
Some owners may hear a whine or hum from the HVAC blower motor when it is turned on.

NOTE:
If a grinding or clicking noise is heard, refer to Technical Information Bulletin 92-T-41 (281202) - Water or Debris Intrusion into Blower Motor.

CAUSE:
The whining or humming noise is caused by the commutator in the blower motor and fan assembly.

CORRECTIVE ACTION:
Install new fan motor cover P/N 21030787.

PROCEDURES

1.

Disconnect blower motor and fan assembly electrical connector.