High Pressure Safety Valve HVAC: Service and Repair

REMOVAL

1. Recover refrigerant using an approved refrigerant recovery system.

CAUTION: DO NOT REMOVE HOSES OR LINES BEFORE SYSTEM IS FULLY DISCHARGED.

2. Remove high side hose bolt from compressor high side and remove hose.

3. Remove pressure relief valve.

INSTALLATION

1. Lubricate pressure relief valve O-ring with new SATURN compressor oil. Install valve and torque to specification.

Torque: 7.2 N.m (63 in-lbs)