SL L4-1.9L SOHC VIN 8 (1997)
d. Using an inside micrometer or gauge ball set SA91102NE (or equivalent), measure the housing bore diameter. Bore diameter standard is
44.475-44.500 mm (1.751-1.752 inch) and service limit is 44.513 mm (1.753 inch) max.
e. Subtract the journal diameter measurement from the housing bore diameter measurement. If the clearance is greater than maximum, replace the
camshaft and/or cylinder head. Oil clearance standard is 0.51-0.101 mm (0.0020-0.0040 inch) and service limit is 0.138 mm (0.0054 inch)
max.
f.
Inspect camshaft bore for flatness. Using a precision straight edge SA 9177NE (or equivalent) and feeler gauge SA 91101 NE (or equivalent),
measure the surfaces contacting the camshaft for warpage. If warpage is greater than maximum, replace the cylinder head. Maximum warpage
standard is 0.05 mm (0.0020 inch) max. and service limit is 0.064 mm (0.0025 inch) max.