SL L4-1.9L SOHC VIN 9 (1991)
Cowl: All Technical Service Bulletins
A/C - Water or Debris Intrusion Into Blower Motor
NO.:
92-T-41
DATE:
August, 1992
GROUP:
HVAC
CORP. NO.:
281202
SUBJECT:
Water or Debris Intrusion into Blower Motor (Install Upper Panel Cowl Seal)
MODELS AFFECTED:
All 1991 and 1992 Saturns
CONDITION:
Some owners of 1991-1992 Saturns may hear a loud noise from the HVAC fan when it is running or notice water dripping from blower motor housing.
CAUSE:
The grinding or clicking noise may be caused by debris such as leaves or twigs that may have entered the ventilation system and are trapped in the fan
housing.
CORRECTIVE ACTION:
Inspect fan housing for debris and remove if present. Install upper panel cowl seal at cowl air inlet.
PROCEDURE
1.
Disconnect blower motor connector.