saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

A/C - Odors at Vehicle Start Up|Page 6786 > < A/C - Odors at Vehicle Start Up|Page 6784
Page 6
background image

6.

With blower motor on HI and engine Off; spray the entire contents of the disinfectant mix. Rotate the nozzle tip up and down while spraying
disinfectant to allow for an even distribution and to ensure full coverage of the evaporator.

7.

Turn blower motor Off.

8.

Allow evaporator core to soak for at least 5 minutes.

9.

With blower motor on HI, thoroughly rinse the evaporator core (using the above procedure) with 1 quart of clean water to remove any disinfectant
residue.

10.

Install hole plug (P/N 21121827).

11.

Properly dispose of disinfectant and rinse water runoff collected in drain pan into a sanitary drain.

12.

Remove protective covering from interior of vehicle.

IMPORTANT: 

Before enabling afterblow function, refer to Customer Information in this bulletin and review operation of afterblow function with customer.

13.

If the delayed blower motor control module is to be installed, proceed to "Delayed Blower Motor Control Module Installation" in this bulletin.

Applying Cooling Coil Coating to Evaporator

APPLYING COOLING COIL COATING (P/N 12346390) TO EVAPORATOR

Perform this procedure only if you are using Cooling Coil Coating (P/N 12346390).

CAUTION:

COOLING COIL COATING CAN CAUSE TEMPORARY EYE INJURY. DO NOT GET COOLING COIL COATING IN EYES OR ON

A/C - Odors at Vehicle Start Up|Page 6786 > < A/C - Odors at Vehicle Start Up|Page 6784