If this component is good, go to the next item indicated on the Symptom Chart.

Circuit 155K

LOCATION: 

Connects ash tray lamp connector cavity B to right body ground splice pack cavity B.

TYPE: 

Black 20 gage wire

FUNCTION: 

This is the ground wire for the ash tray lamp bulb.

REPAIRS:

Check for OPEN or SHORTS

Repair as needed.

If this component is good, go to the next item indicated on the Symptom Chart.

Circuit 155A

LOCATION: 

Connects Perf/Norm switch connector cavity B to right body ground splice pack cavity E.

TYPE: 

Black 22 gage wire

FUNCTION: 

This is the ground wire for the Perf/Norm switch lamp bulb.

REPAIRS:

Check for OPENS/SHORTS.

Repair as needed.

If this component is good, go to the next item indicated on the Symptom Chart.

Circuit 155B

LOCATION: 

Connects PRNDL lamp connector cavity A to right body ground splice pack cavity E.

TYPE: 

Black 22 gage wire

FUNCTION: 

This is the ground wire for the PRNDL lamp bulb.

REPAIRS:

Check for OPENS/SHORTS.

Repair as needed.

If this component is good, go to the next item indicated on the Symptom Chart.

Circuit 154B

LOCATION: 

Connects HVAC module connector cavity A to instrument panel junction block connector cavity A.

TYPE: 

Black 22 gage wire

FUNCTION: 

This is the ground wire for the HVAC module dim illumination bulbs. It is ground in the instrument panel junction block.

Diagnostic Trouble Code Tests and Associated Procedures|Page 9112 > < Diagnostic Trouble Code Tests and Associated Procedures|Page 9110