saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Diagnostic Trouble Code Tests and Associated Procedures|Page 9261 > < Diagnostic Trouble Code Tests and Associated Procedures|Page 9259
Page 13
background image

REPAIRS:

Check for OPEN or SHORTS

Repair as needed.

If this component is good, go to the next item indicated on the Symptom Chart.

Circuit 8J

LOCATION: 

Connects I/P junction block connector cavity C1 to I/P cluster connector cavity V

TYPE: 

Gray 22 gage wire

FUNCTION: 

This circuit supplies battery voltage to the I/P cluster illumination lamp.

REPAIRS:

Check for OPEN or SHORTS

Repair as needed.

If this component is good, go to the next item indicated on the Symptom Chart.

Circuit 8K

LOCATION: 

Connects I/P junction block connector cavity B1 to cigar lighter lamp connector cavity A.

TYPE: 

Gray 22 gage wire

FUNCTION: 

This circuit supplies battery voltage to the cigar lighter lamp.

REPAIRS:

Check for OPEN or SHORTS

Repair as needed.

If this component is good, go to the next item indicated on the Symptom Chart.

Circuit 8H

LOCATION: 

Connects I/P junction block connector cavity B2 to radio connector cavity 7.

TYPE: 

Gray 22 gage wire

FUNCTION: 

This circuit supplies battery voltage to the radio display dim illumination lamp.

REPAIRS:

Check for OPEN or SHORTS

Repair as needed.

If this component is good, go to the next item indicated on the Symptom Chart.

Circuit 8L

LOCATION:

Diagnostic Trouble Code Tests and Associated Procedures|Page 9261 > < Diagnostic Trouble Code Tests and Associated Procedures|Page 9259