saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Diagnostic Trouble Code Tests and Associated Procedures|Page 9281 > < Diagnostic Trouble Code Tests and Associated Procedures|Page 9279
Page 33
background image

Repair as needed.

If this component is good, go to the next item indicated on the Symptom Chart.

Circuit 8B

LOCATION:

Connects I/P junction block connector cavity C to HVAC connector cavity B.

TYPE: 

Gray 22 gage wire

FUNCTION: 

This circuit supplies battery voltage to the HVAC module dim illumination lamps.

REPAIRS:

Check for OPEN or SHORTS

Repair as needed.

If this component is good, go to the next item indicated on the Symptom Chart.

Circuit 9J

LOCATION: 

Connects underhood junction block connector cavity B4 to I/P junction block connector cavity E5.

TYPE: 

Brown 22 gage wire.

FUNCTION: 

This circuit supplies battery voltage to the I/P junction block.

REPAIRS:

Check for OPEN or SHORTS

Repair as needed.

If this component is good, go to the next item indicated on the Symptom Chart.

Circuit 8A

LOCATION: 

Connects the HVAC unit heater to the HVAC unit bulbs.

TYPE: 

Gray 22 gage wire.

FUNCTION: 

This circuit supplies battery power to the bulbs in the HVAC unit.

REPAIRS:

Check for OPEN or SHORTS

Repair as needed.

If this component is good, go to the next item indicated on the Symptom Chart.

Circuit 154C

LOCATION: 

Connects HVAC unit to HVAC unit heater only connector.

Diagnostic Trouble Code Tests and Associated Procedures|Page 9281 > < Diagnostic Trouble Code Tests and Associated Procedures|Page 9279