saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Shift Interlock Solenoid|Locations|Page 4371 > < Shift Interlock Solenoid|Locations|Page 4369
Page 1
background image

Shift Interlock Solenoid: Testing and Inspection

BTSI Solenoid: I/P To Body Inline Connector

Check solenoid connector for open spread or corroded terminals.

^

Test Solenoid:

Ground terminal "B" of solenoid and apply 12 volts to terminal "A". Solenoid should pull in. If the solenoid does not pull in, replace solenoid.

Shift Interlock Solenoid|Locations|Page 4371 > < Shift Interlock Solenoid|Locations|Page 4369