Air Door Actuator / Motor: Service and Repair

REMOVAL

1. Remove recirc motor electrical connection.
2. Remove recirc motor mounting screws.
3. Pull motor straight off of recirc door shaft.

INSTALLATION

1. Position recirc door to outside air.
2. Align flats on motor shaft and recirc door shaft.
3. Push motor straight on recirc door shaft while rotating back and forth to engage recirc door shaft into recirc motor.
4. Install mounting screws.

Torque: 1.7 N.m (15 in-lbs)

5. Install electrical connector.

Air Door Cable, HVAC > < Air Door Actuator / Motor, HVAC|Specifications|Page 8763