Tachometer: Service and Repair
Removal

Speedometer Or Tachometer Removal

NOTE:  Failure to use the anti-static mat SA 9502Z properly will result in damage or latent damage to the cluster electronics.

IMPORTANT:  

^

If the lens/mask gets dirty it can be cleaned by following the procedures in this manual. If a dial face gets dirty it can be cleaned by using glass
cleaner and a lint free rag.

^

Do not touch or bump the pointers of the gages. If the pointers arc moved from their positions the calibration of the gage will be affected, and the
gage will no longer be accurate and must be replaced.

1. Remove instrument panel cluster assembly. 
2. Thoroughly clean hands with soap and water to remove any oil or other substances which could damage the cluster. If unable to clean hands, an

alternative is to wear surgical gloves during all procedures.

IMPORTANT:  It is strongly recommended that rubber gloves (i.e., like surgical gloves) be worn while performing removal and installation procedures
to prevent grease, smudges, scratches and fingerprints.

3. Place anti-static mat SA 9502Z down on the work area. In order to ground the mat connect the alligator clip to a large metal object (e.g., work

bench) making sure that the attaching point is a bare metal surface and not painted or coated. Also put the wrist strap around one of your wrists.

4. Place a clean, dry, soft material such as a cloth baby diaper on top of the anti-static mat.
5. Place instrument panel cluster assembly face down on the cloth and the anti-static mat.
6. Insert the curved jaw of the tool, SA9701Z, under the speedometer flex printed circuit board connection.
7. Position the vise grips so that the paddles, welded to jaws, cover the exposed crimps (coming through copper traces).
8. Gently pull away from the cluster in a direction parallel to the back surface of the cluster.

For tachometer replacement, refer to steps 9 through 11. If tachometer is not being removed, go to step 12.

Speedometer Or Tachometer Removal

9. Using SA 9507Z curved needlenose pliers remove flex printed circuit board (PCB) tab from locater tab under tachometer.

10. With SA 9507Z pliers, grasp across terminals on both sides of the flex PCB.
11. Gently pull connector straight out from housing.