SW2 L4-1.9L DOHC VIN 7 (1997)
-
CONNECT THE DEPLOYMENT HARNESS TO THE INFLATOR MODULE BEFORE YOU CONNECT IT TO THE POWER SOURCE.
-
CONNECT THE DEPLOYMENT HARNESS TO THE POWER SOURCE TO IMMEDIATELY DEPLOY THE AIR BAG.
FAILURE TO FOLLOW THE PROCEDURES IN THE ORDER LISTED MAY RESULT IN PERSONAL INJURY.
1. Short the two universal deployment harness leads together by fully seating one banana plug into the other. Universal deployment harness shall
remain shorted and not be connected to a power source until the air bag is to be deployed.
2. Connect the appropriate pigtail adapter to the universal deployment harness.
3. Remove inflator module from vehicle.
4. Temporarily place the inflator module on a work bench or other surface away from all loose or flammable objects and with its soft vinyl trim cover
facing up, away from the surface.
5. Clear a space on the ground approximately six feet in diameter where the inflator module is to be deployed. A paved outdoor location where there
is no activity and sufficient ventilation is recommended. Make certain that no loose or flammable objects are within the deployment area.
6. Place the inflator module with a soft vinyl trim cover facing up on the ground in the space just cleared.