INSTALLATION PROCEDURE

1. Add the proper amount of polyalkylene glycol (PAG) oil to the evaporator core. Refer to Refrigerant System Capacities.
2. Inspect the seal around the evaporator core. Make sure the seal is in correct position and retained properly.
3. Spray the seal with a soap and water mixture to ease the installation of evaporator core.
4. Install the evaporator core to the blower case assembly.

5. Install the evaporator pipe cover.
6. Install the evaporator pipe cover screw.

Tighten the screw to 1 N.m (9 lb in).

NOTE:  Refer to Fastener Notice in Service Precautions.