saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 4555 > < Diagram Information and Instructions|Page 4553
Page 24
background image

7. Insert the wire into the duraseal splice sleeve barrel until the wire hits the barrel stop. 
8. Tightly close the handles of the crimp tool until the crimper handles open when released.The crimper handles will not open until you apply the

proper amount of pressure to the duraseal splice sleeve. Repeat steps 4 and 5 for the opposite end of the splice.

9. Using the heat torch, apply heat to the crimped area of the barrel.

10. Gradually move the heat barrel to the open end of the tubing:

-

The tubing will shrink completely as the heat is moved along the insulation.

-

A small amount of sealant will come out of the end of the tubing when sufficient shrinkage is achieved.

CONNECTOR POSITION ASSURANCE (CPA)

The connector position assurance (CPA) is a small plastic insert that fits through the locking tabs of all the SIR/SRS system electrical connectors. The
CPA ensures that the connector halves cannot vibrate apart. You must have the CPA in place in order to ensure good contact between the SIR/SRS
mating terminals.

TERMINAL POSITION ASSURANCE (TPA)

The terminal position assurance (TPA) insert resembles the plastic combs used in the control module connectors. The TPA keeps the terminal securely
seated in the connector body. Do not remove the TPA from the connector body unless you remove a terminal for replacement.

Splicing Copper Wire Using Splice Sleeves

SPLICING COPPER WIRE USING SPLICE SLEEVES

TOOLS REQUIRED

-

Crimp tool 

-

Heat torch

IMPORTANT:  Use only duraseal splice sleeves. Other splice sleeves may not protect the splice from moisture or provide a good electrical
connection.

Use duraseal splice sleeves to form a one-to-one splice on all types of insulation except tefzel and coaxial. Use duraseal splice sleeves where there is
special requirements such as moisture sealing. Follow the instructions below in order to splice copper wire using crimp and seal splice sleeves.

Diagram Information and Instructions|Page 4555 > < Diagram Information and Instructions|Page 4553