Fuel Pump > < Fuel Pressure Pulsation Damper|Description and Operation|Page 5217
Page 3
background image

3. Install the fuel pressure regulator into the fuel rail.
4. Install the retaining bolts.

NOTE:  Refer to Fastener Notice in Service Precautions.

Tighten the fuel pressure dampener bolts to 5 N.m (44 lb in).

5. Install the outlet resonator/duct assembly into position.
6. Connect the PCV fresh air vent hose assembly.
7. Tighten the clamp at the throttle body assembly.
8. Position the outlet resonator/duct assembly up with a support bracket and install the push pin.
9. Tighten the clamp at the air cleaner assembly.

10. Connect the air intake temperature (IAT) sensor connector.
11. Connect the negative battery cable.

Tighten the battery terminal bolt to 17 N.m (13 lb ft).

12. Run the vehicle and inspect for leaks.

Fuel Pump > < Fuel Pressure Pulsation Damper|Description and Operation|Page 5217