saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Throttle Position Sensor > < Heated Oxygen Sensor (HO2S) 1 Replacement|Page 1002
Page 2
background image

1. Apply a small amount of anti-seize compound Saturn P/N 21485279, or equivalent, to the threads of the HO2S-2.

NOTE:  Silicone based products will contaminate the HO2S. Use only a nickel based anti-seize compound that does not contain silicone.

2. Install the HO2S-2 using the J 39194-C, or equivalent.

NOTE:  Refer to Fastener Notice in Service Precautions.

Tighten the HO2S-2 sensor-to-exhaust pipe to 45 N.m (33 lb ft).

3. Install the HO2S-2 harness clip to the heat shield attachment bolt.

NOTE:  Do Not apply any material in the HO2S-2 harness connector such as grease or dielectric compound. The wires carry air reference to the
sensor in order for the sensor to operate properly.

Tighten the bolt to 4 N.m (35 lb in).

4. Connect the HO2S-2 harness connector. Push in the connector until a click is heard, then pull back to confirm a positive engagement.
5. Ensure the HO2S-2 harness pigtail connector is secure to the chassis.

Throttle Position Sensor > < Heated Oxygen Sensor (HO2S) 1 Replacement|Page 1002