1. Locate the lever lock on the wire dress cover. While pressing the lock, pull the lever over and past the lock.
2. Disconnect the connector from the component.

3. Locate the 2-wire dress cover locking tabs that are opposite the wire end of the connector. Use a small flat-bladed tool to unlock the dress cover.
4. Once the front 2 locks are unlocked, lift the back 2 locks that are on the wire side of the connector.

5. If the connector has a nose piece, use a small flat-bladed tool to remove the nose piece by inserting the blade into the slot on the front of the

connector and prying up on the nose piece.

IMPORTANT:  Always use care when removing a terminal positive assurance (TPA) in order to avoid damaging it.

6. Remove the TPA by inserting a small flat-bladed tool into the small slot on the TPA and pushing down until the TPA comes out of the connector.

Gently pry the TPA out of the connector.

7. Insert the J 44020-4 (GM P/N 15314260) tool into the 2 triangular cavities on each side of the terminal at the front of the connector.

Diagram Information and Instructions|Page 1291 > < Diagram Information and Instructions|Page 1289