Heated Glass Element: Component Tests and General Diagnostics

 
DEFOGGER GRID LINES DIAGNOSIS

IMPORTANT:  This test is for reference only. A grid line fault requires rear window replacement. Refer to Window Replacement - Liftgate.

1. Start the engine.
2. Activate the rear window defogger system.
3. Connect a test lamp to a good ground.

4. Move the test lamp probe from the positive to the negative wire.

-

If the test lamp shows full brilliance at both ends of the grid lines, inspect for an open or poor connection in the ground circuit of the rear
window defogger grid. 

-

If the test lamp goes out, test the grid line in at least 2 places to eliminate the possibility of bridging the open in the grid line.

IMPORTANT:  The test lamp brilliance will decrease proportionately to the increased resistance in the grid line as the probe is moved from the
battery positive bus wire to the ground bus wire. The test lamp brilliance may vary from one window to another.

5. Once the open is located, replace the rear window. Refer to Window Replacement - Liftgate .