saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Air Duct > < Air Temperature Actuator Replacement|Page 12329
Page 1
background image

Air Door Actuator / Motor: Service and Repair
Recirculation Actuator Replacement

Recirculation Actuator Replacement

Removal Procedure

1. Remove the right side insulator/closeout panel.
2. Disconnect the electrical connector from the recirculation actuator.
3. Remove the recirculation actuator screws from the HVAC module.
4. Remove the recirculation actuator from the HVAC module.

Installation Procedure

1. Align the recirculation actuator with the door shaft and rotate into position.

Notice:  Refer to Fastener Notice.

2. Install the recirculation actuator screws to the HVAC module.

Tighten the screws to 1 N.m (9 lb in).

3. Connect the electrical connector to the recirculation actuator.
4. Cycle the ignition and verify proper operation.
5. Install the right side insulator/closeout panel.

Air Duct > < Air Temperature Actuator Replacement|Page 12329