Fuel Line Coupler: Service and Repair
Plastic Collar Quick Connect Fitting Service (Plastic Collar Lever Release)

Plastic Collar Quick Connect Fitting Service (Plastic Collar Lever Release)

Removal Procedure

Caution:  Wear safety glasses when using compressed air, as flying dirt particles may cause eye injury.

1. Blow dirt out of the fitting using compressed air.

2. Depress the retaining tab (2) while holding the connector housing (1).

3. Continue to depress the retaining tab while pulling the connector apart.

Notice:  If necessary, remove rust or burrs from the fuel pipes with an emery cloth. Use a radial motion with the fuel pipe end in order to prevent
damage to the O-ring sealing surface. Use a clean shop towel in order to wipe off the male tube ends. Inspect all the connections for dirt and burrs.
Clean or replace the components and assemblies as required.

4. Wipe off the male end using a clean shop towel.
5. Inspect both ends of the fitting for dirt and burrs.
6. Clean or replace the components as required.

Installation Procedure

Caution:  In order to reduce the risk of fire and personal injury, before connecting fuel pipe fittings, always apply a few drops of clean

Metal Collar Quick Connect Fitting Service|Page 7136 > < Metal Collar Quick Connect Fitting Service|Page 7134