Air Door Actuator / Motor: Service and Repair
Panel Actuator

PANEL ACTUATOR REPLACEMENT

REMOVAL PROCEDURE

1. Remove the instrument panel compartment.
2. Disconnect the electrical connector from the panel actuator.
3. Remove the panel actuator screws from the HVAC module.
4. Remove the panel actuator from the HVAC module.

INSTALLATION PROCEDURE

1. Align the panel actuator with the door shaft and rotate into position.

NOTE:  Refer to Fastener Notice in Service Precautions.