Fuel Line Coupler: Service and Repair
Quick Connect Fitting(S) Service (Plastic Collar) (Plastic Collar)

QUICK CONNECT FITTING(S) SERVICE (PLASTIC COLLAR) (PLASTIC COLLAR)

REMOVAL PROCEDURE

1. Relieve the fuel system pressure. Refer to Fuel Pressure Relief Procedure.
2. Blow dirt out of the fitting using compressed air.

CAUTION:  Wear safety glasses when using compressed air in order to prevent eye injury.

3. Squeeze the plastic tabs of the male end connector.

4. Pull the connection apart.
5. Wipe off the male pipe end using a clean shop towel.

NOTE:  Use an emery cloth in order to remove rust or burrs from the fuel pipe. Use a radial motion with the fuel pipe end in order to prevent damage
to the O-ring sealing surface.

6. Inspect both ends of the fitting for dirt and burrs.
7. Clean or replace the components as required.

INSTALLATION PROCEDURE

CAUTION:  In order to reduce the risk of fire and personal injury, before connecting fuel pipe fittings, always apply a few drops of clean