saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 3378 > < Diagram Information and Instructions|Page 3376
Page 1
background image

Variable Valve Timing Solenoid: Service and Repair

Camshaft Position Actuator Solenoid Valve Replacement

Removal Procedure

1. Remove the air cleaner outlet duct. Refer to Air Cleaner Outlet Duct Replacement  (See: Tune-up and Engine Performance Checks/Air Cleaner

Housing/Air Cleaner Fresh Air Duct/Hose/Service and Repair/Air Cleaner Outlet Duct Replacement) .

2. Disconnect the engine wiring harness electrical connectors (2, 3) from the appropriate camshaft position (CMP) actuator solenoid valve.

3. Remove the exhaust CMP actuator solenoid valve bolt and valve (1), if required.
4. Remove the intake CMP actuator solenoid valve bolt and valve (2), if required.
5. Inspect the CMP actuator solenoid valve O-ring seals for damage, replace as necessary.

Installation Procedure

Diagram Information and Instructions|Page 3378 > < Diagram Information and Instructions|Page 3376