Air Door Actuator / Motor: Service and Repair
Defroster Actuator Replacement

Defroster Actuator Replacement

Removal Procedure

1. Remove the left side insulator/closeout panel.
2. Remove the communication interface module, if equipped.
3. Disconnect the electrical connector from the defroster actuator.
4. Remove the defroster actuator screws from the HVAC module.
5. Remove the defroster actuator from the HVAC module.

Installation Procedure

1. Align the defroster actuator with the defroster door shaft and rotate into position.

Notice:  Refer to Fastener Notice.

2. Install the defroster actuator screws to the HVAC module.

Tighten the screws to 1 N.m (9 lb in).

3. Connect the electrical connector to the defroster actuator.
4. Install the communication interface module, if equipped.
5. Install the left side insulator/closeout panel.

Important:  Any time a mode actuator or the HVAC control module is replaced, the HVAC control module must be calibrated to ensure