saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Hybrid System - MIL/Battery Lamp ON/DTC's P1A5A/P1A59|Page 4375 > < Hybrid System - MIL/Battery Lamp ON/DTC's P1A5A/P1A59
Page 2
background image

For vehicles repaired under warranty use, the table.

Disclaimer

VUE

Service Procedure (VUE)

Dust may be an irritant to skin and eyes. Avoid skin and eye contact. If battery dust is present, remove carefully to avoid inhalation. Wear safety glasses
and butyl rubber, natural rubber, neoprene, nitrile or Tyvek protective gloves when handling any corroded hybrid batteries and when cleaning the inside
of the hybrid battery case. Discard the gloves after each use and dispose of any corrosion material that was removed from the case.

Remove the ignition key from the ignition switch. Secure the ignition key in order to ensure that the key CANNOT be re-installed without your
knowledge.

Disconnect the 12 volt negative battery cable.

Remove the rear compartment closeout panels.

Remove the generator battery disconnect control module cover bolt

Slide the generator battery disconnect control module cover to the right and remove the cover. WAIT at least 5 minutes in order to allow the generator
control module capacitors to discharge.

Hybrid System - MIL/Battery Lamp ON/DTC's P1A5A/P1A59|Page 4375 > < Hybrid System - MIL/Battery Lamp ON/DTC's P1A5A/P1A59