Disconnect the generator battery temperature sensor wiring harness electrical connectors (1) from the battery temperature sensors. 

Cut the tie straps securing the battery cables to the generator battery temperature sensor wiring harness.

Disconnect the generator battery temperature sensor wiring harness electrical connectors (2, 5) from the generator control module.

Remove the generator battery temperature sensor wiring harness.

Remove the remaining generator battery cable from the battery.

Remove all the mounting bolts (1) from the 3 generator batteries.

Each failed hybrid battery must be placed in two (double) polyethylene 6 mil bags that were provided with the new batteries. If the bags were not
included with the batteries, contact your Saturn Parts Service Analysis (PSA) or the Saturn Saab Service Parts Assistance Centre (SPAC) for Canadian
retailers. This double bagging procedure must be performed as soon as the hybrid batteries are removed from the vehicle. After bagging the individual
battery cassettes, place the batteries in the original shipping container. After the warranty claim is paid, these parts will be requested to be returned
through the GM Warranty Parts Center (WPC) process (Refer to Returning the Battery to the WPC below). Place the WPC request number on the
outside of the shipping box. Hybrid battery cassettes are not to be shipped or returned until they are double bagged.

Remove all 3 generator batteries.

Remove the 3 temperature sensors from the batteries.

Remove the four generator battery control module assembly bolts.

Remove the generator battery control module assembly from the carrier.

Hybrid System - MIL/Battery Lamp ON/DTC's P1A5A/P1A59|Page 4379 > < Hybrid System - MIL/Battery Lamp ON/DTC's P1A5A/P1A59|Page 4377