Dust may be an irritant to skin and eyes. Avoid skin and eye contact. If battery dust is present, remove carefully to avoid inhalation. Wear safety glasses
and butyl rubber, natural rubber, neoprene, nitrile or Tyvek protective gloves when handling any corroded hybrid batteries and when cleaning the inside
of the hybrid battery case. Discard the gloves after each use and dispose of any corrosion material that was removed from the case.

Remove the ignition key from the ignition switch. Secure the ignition key in order to ensure that the key CANNOT be re-installed without your
knowledge.

Disconnect the 12 volt negative battery cable.

Fold down both rear seat backs.

Carefully lift up on the load floor rear compartment cover (1) at the retaining clip (2) locations.

Tilt the load floor rear compartment cover (2) towards the rear of the vehicle slightly disengaging the tabs (1) and remove the load floor rear
compartment cover.

Remove the generator battery disconnect control module cover bolt.

Slide the generator battery disconnect control module cover to the right and remove the cover. WAIT at least 5 minutes in order to allow the generator
control module capacitors to discharge.