saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Recall - Loss of Hybrid Function|Page 4328 > < Recall - Loss of Hybrid Function|Page 4326
Page 5
background image

Important:

Never assume the battery pack is disabled when the generator battery disconnect control module cover is opened.

7.

The generator battery will have to be checked for voltage potential using a voltmeter. First, verify that the voltmeter works.

1.

Set the voltmeter to DC voltage.

2.

Measure the vehicle's 12-volt battery voltage (at 12-volt positive jumper location and negative battery cable).

3.

The meter should read greater than +12 volts DC.

8.

Now, check the generator battery for voltage potential in order to ensure that the generator battery has been disabled.

1.

Measure from the positive (3) stud to the negative stud (2). The voltage should be less than 3 volts.

2.

Measure from the positive (3) stud to the vehicle chassis ground (1). The voltage should be less than 3 volts.

3.

Measure from the negative (2) stud to the vehicle chassis ground (1). The voltage should be less than 3 volts.

4.

After verifying that there is no voltage present, the vehicle is now safe to work on.

9.

Remove the driver and passenger side rear compartment load floor stowage tray retainers (1, 3).

10.

Remove the driver and passenger side rear compartment load floor stowage trays (2, 4).

Recall - Loss of Hybrid Function|Page 4328 > < Recall - Loss of Hybrid Function|Page 4326