21.

Remove the two upper generator battery fan bolts (2).

22.

Remove the 12 generator battery cover bolts (1).

23.

Remove the generator battery wiring harness from the clip (3) on the generator battery cover.

24.

Remove the generator battery cover.

Important:

Removing the interconnect cables will disable the 36 volts within the generator battery control module.